Cavity Walls: U Values (W/m2K) for Clear Cavity Walls Constructed Using Rendered Outer Leaf 1500kg/m

Inner Leaf: With 10mm Joints

Solar

JumboPlus

Normal/Plus

Internal Finish

100 (mm)

115 (mm)

125 (mm)

100 (mm)

115 (mm)

125

(mm)

150 (mm)

200 (mm)

40mm ThermaLine Plus

0.40

0.38

0.37

0.41

0.39

0.38

0.35

0.32

60mm Thermaline PLATINUM

0.33

0.32

0.31

0.34

0.32

0.32

0.30

0.27

50mm ThermaLine SUPER

0.31

0.30

0.39

0.31

0.30

0.30

0.28

0.26

65mm ThermaLine SUPER

0.25

0.24

0.24

0.25

0.25

0.24

0.23

0.21

U-Values for Clear Cavity Walls Using Celcon Standard Aircrete Blocks

Inner Leaf: With 10mm Joints

Standard

JumboPlus

Normal/Plus

Internal Finish

100 (mm)

115 (mm)

100 (mm)

115 (mm)

125 (mm)

150 (mm)

40mm ThermaLine Plus

0.43

0.41

0.44

0.42

0.41

0.39

60mm Thermaline PLATINUM

0.36

0.34

0.36

0.35

0.34

0.32

50mm ThermaLine SUPER

0.33

0.32

0.33

0.32

0.32

0.30

65mm ThermaLine SUPER

0.26

0.26

0.27

0.26

0.26

0.25

U-Values for Clear Cavity Walls Using Celcon Hi-Strength Aircrete Blocks

Inner Leaf: With 10mm Joints

Hi-Strength

JumboPlus

Normal/Plus

Internal Finish

100

(mm)

100

(mm)

125

(mm)

190

(mm)

40mm ThermaLine Plus

0.46

0.46

0.44

0.39

60mm Thermaline PLATINUM

0.37

0.37

0.38

0.32

50mm ThermaLine SUPER

0.34

0.34

0.33

0.30

65mm ThermaLine SUPER

0.27

0.27

0.26

0.25

Block format:
Normal: 440mm long x 215mm high
Plus: 610mm long x 215mm high
JumboPlus: 610mm long x 270mm high

440 x 215 x 100mm blocks with 10mm joints

This information has been sourced, reviewed and adapted from materials provided by H + H Celcon.

For more information on this source, please visit H + H Celcon.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    H + H Celcon. (2019, April 23). Cavity Walls: U Values (W/m2K) for Clear Cavity Walls Constructed Using Rendered Outer Leaf 1500kg/m. AZoBuild. Retrieved on November 21, 2024 from https://www.azobuild.com/article.aspx?ArticleID=7892.

  • MLA

    H + H Celcon. "Cavity Walls: U Values (W/m2K) for Clear Cavity Walls Constructed Using Rendered Outer Leaf 1500kg/m". AZoBuild. 21 November 2024. <https://www.azobuild.com/article.aspx?ArticleID=7892>.

  • Chicago

    H + H Celcon. "Cavity Walls: U Values (W/m2K) for Clear Cavity Walls Constructed Using Rendered Outer Leaf 1500kg/m". AZoBuild. https://www.azobuild.com/article.aspx?ArticleID=7892. (accessed November 21, 2024).

  • Harvard

    H + H Celcon. 2019. Cavity Walls: U Values (W/m2K) for Clear Cavity Walls Constructed Using Rendered Outer Leaf 1500kg/m. AZoBuild, viewed 21 November 2024, https://www.azobuild.com/article.aspx?ArticleID=7892.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this article?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.